Shakespeare Composite Structures
Transmission and Distribution Tuff-Poles®
 

Appendix G
 
Item Tested
5/8² BOLT THRU WALL OF TYPICAL DISTRIBUTION TYPE POLE
Test Report No.
T&D BOLT
Type Test
BOLT HOLE BEARING TEST
Page 1 OF 1
Purpose of Test
TO DETERMINE LOAD BEARING CAPACITY OF BOLT THRU POLE WALL
Drawing No.

Results of Test

LOAD WAS INCREASED TO 5000 LB AND RELEASED.

INSPECTION OF THE BOLT HOLE REVEALED SOME LOCALIZED FAILURE
OF THE LAMINATE WITHIN 1/2² OF THE HOLE

Tested By:
J. BOOZER
Reported By:
J. BOOZER
Approved By:
JOHN F. BOOZER III


Shakespeare Composite Structures
a Genlyte company
19845 Highway 76, Newberry, SC 29108 · 803.276.5504 Fax: 803.276.8940